Standard Operating Manual

Standard Operating Manual

4. Operating Procedures 4.1 System Description 4.2 Safety Warning 4.3 Operation Precautions and Rules 4.4 Initial Status Checks 4.5 Initial System Checks 4.6 Vacuum Oven Operation Procedure 4.6.1 Operation in a Static Environment 4.6.2 Operation in a Nitrogen Environment 4.6.3 Operating in a Vacuum Environment 4.7 Clean Up 4.8 Check out

More Product
Standard Operating Procedure

Standard Operating Procedure

5. Stop oven. 6. Rinse inside of oven with shower spray attached to oven. 7. Wipe inside of door with paper towel, then with a damp cloth. 8. Dry oven using convection mode for 5 minutes. 9. Leave door ajar. Cleaning solution may cause irritation to skin and eyes. Spraying hot oven with cleaning solution will damage the metal interior. Use of ...

More Product
Drying Oven Calibration Procedure

Drying Oven Calibration Procedure

5.0 PROCEDURE 5.1 Tightly close the door of the oven. 5.2 Switch on the instrument. 5.3 Set desired temperature using temperature control knob. 5.4 Allow the instrument to reach the desired temperature. 5.5 Switch off the instrument and place substance to be dried into the oven. 5.6 Close the door tightly switch on the instrument.

More Product
Procedure for Operation and Calibration of Lab Oven

Procedure for Operation and Calibration of Lab Oven

5.0 Procedure: 5.1 Operating Procedure of Lab Oven: 5.1.1 The lab oven is used for sterilization of sampling flasks, glassware and instruments (scissors, spatulas, and forceps etc.) at 181 C for 2 hours. 5.1.2 Arrange petri plates in closed SS trays, instruments (pipette, scissors and forceps) in SS pipette jar. Keep pipette jars and sampling ...

More Product
Procedure for operation cleaning and calibration of hot air oven

Procedure for operation cleaning and calibration of hot air oven

5.2 CLEANING. 5.2.1 Put ‘OFF’ the Heating, MAINS switch and disconnect the power supply respectively. 5.2.2 Empty the Hot Air Oven by removing all the materials present inside it. 5.2.3 Clean the inner walls and trays using wet mop followed by …

More Product
Standard Operating Procedure For Drying Oven

Standard Operating Procedure For Drying Oven

Dec 07, 2020 Most of the medical industries use hot air ovens to sterilize laboratory instruments and material due to its simple standard operating procedure and low price. It also provides quick-drying processes. The process of dry heat sterilization using a hot air oven Originally developed by Louis Pasteur. Get Details

More Product
SOP FOR OPERATION AND CALIBRATION OF HOT AIR OVEN

SOP FOR OPERATION AND CALIBRATION OF HOT AIR OVEN

Dec 16, 2017 4.2.1 For the calibration of Hot Air Oven use a standard thermometer ranging upto 200 0. 4.2.2 Set the oven at desired temperature. 4.2.3 Start the calibration procedure after the oven reaching the set temperature through the passage providing in the right and left side. 4.2.4 Put the standard thermometer for 15 minutes in upper shelf of oven ...

More Product
NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE FOR DRYING ...

NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE FOR DRYING ...

Dec 22, 2005 This procedure describes the calibration and maintenance activities of an oven custodian in ensuring that ovens are functioning properly. Drying ovens were used for removing residual water and/or solvents from labware and reagents. Removal of such substances from either labware or chemicals was often necessary for successful analysis or reaction.

More Product
Total Dissolved Solids by Gravimetric Determination

Total Dissolved Solids by Gravimetric Determination

drying step and capable of maintaining a temperature 100 C (preferably at 80 C) to prevent sample boiling. e. Convection oven operated at 80 C (optional) for evaporating samples in a pre-drying step. f. Convection oven operated at 180 2C for drying samples to a constant weight condition. g. Muffle furnace operated at 550 50 C. h.

More Product
INSTRUCTION MANUAL FOR VACUUM DRYING OVENS

INSTRUCTION MANUAL FOR VACUUM DRYING OVENS

initial operation of your VACUUM drying oven. This will ensure proper operating procedures and extended life for the unit. Please keep the operating instructions together with the warranty card for easy access whenever you need them. Attention: Read the warnings in the operating instructions carefully to familiarize yourself with the initial ...

More Product
SOP (Standard Operating Procedure) of hot air oven

SOP (Standard Operating Procedure) of hot air oven

Jan 18, 2022 The SS trays should be cleaned with iso-propyl alcohol using lint-free cloth.STANDARD OPERATIONAL PROCEDURESwitching On Procedure -I. Ensure that gas/air flow cylinders are ON from facility side.II. Turn ON the Rota meter for air flow in the oven.III. Switch ON the Mains of the Oven.IV. Turn ON the mains.

More Product
SOP: Flammable Liquids - PennEHRS

SOP: Flammable Liquids - PennEHRS

Jan 24, 2022 Standard Operating Procedures. SOP: Acutely Toxic Chemicals; SOP: Carcinogens; SOP: Compressed Gases ... a dedicated laboratory exhaust to reduce the hazard of accumulating an explosive mixture of flammable vapor within the oven. Drying ovens should not be used to dry glassware that has been rinsed with organic solvents until the majority of ...

More Product
Industrial Ovens Operation Maintenance Manual

Industrial Ovens Operation Maintenance Manual

operating a powder oven. Caution needs to be used when transporting product in and out of the oven. Temperatures in the oven can exceed 400 F. The oven is designed to replace 20% of the air with fresh air in order to maintain low levels of CO, but caution should be used in case of an unsafe CO level inside of oven. 1.2.2 House Keeping

More Product
Oven Standard Operating Procedure (SOP)

Oven Standard Operating Procedure (SOP)

oven chamber, caution must be taken to ensure that the components that create the vacuum are compatible with vapors that may be produced in the oven (i.e. vacuum pump seals must be tolerant of any fumes from the oven). General Operating Procedure 1. Input the desired temperature setpoint using the oven’s interface 2.

More Product
Laboratory Safety Standard Operating Procedure (SOP)

Laboratory Safety Standard Operating Procedure (SOP)

Person who perform this procedure should be trained by an experienced graduated students, and have permission from the person in charge of the vacuum oven. Make sure that the connection direction of the trap is correct. Laboratory Safety Standard Operating Procedure (SOP) (for the use of hazardous materials or equipment)

More Product
Standard Operating Procedure (SOP) 3.3.2 - California

Standard Operating Procedure (SOP) 3.3.2 - California

Standard Operating Procedure (SOP) 3.3.2.1. By Erick Burres . ... Fresh standard should be prepared each time unless ... • Stock Nitrate Solution: Dry KNO 3 (potassium nitrate) in an oven for 24 hours at 105 C. Then dissolve 3.62 g of KNO 3 in distilled water. Dilute to 500 mL in your 500 mL graduated cylinder using distilled water. Carefully

More Product
Isotemp Oven OV700G SOP - engineering.iastate.edu

Isotemp Oven OV700G SOP - engineering.iastate.edu

Standard Operating Procedure Procedure: Isotemp Oven OV700G Department: Bioeconomy Institute Building/ Room Number: Biorenewables Research Laboratory (BRL) 1114 Supervisor: Jacqulyn Baughman Procedure Overview: An Isotemp oven is a laboratory product designed to be used for programmed tasks or simple, routine heating tasks. For example: drying ...

More Product
STANDARD OPERATING PROCEDURE - EDGE

STANDARD OPERATING PROCEDURE - EDGE

STANDARD OPERATING PROCEDURE. SOP Description Total Suspended Solids. Document Name TSS TVSS. Revision #3b. MWC_SOP_TSS_TVSS_rev3b.doc. Method: SM 18-20 2540D. ... While vacuum is applied, wash filter with three 20 mL portions of distlled water, suction dry. Dry in an oven at 103-105 C for an hour before use, and / or store in oven at 103 ...

More Product
STANDARD OPERATING PROCEDURES - CLU-IN

STANDARD OPERATING PROCEDURES - CLU-IN

STANDARD OPERATING PROCEDURES SOP: 2034 PAGE: 1 of 5 REV: 0.0 DATE: 11/17/94 PLANT BIOMASS DETERMINATION CONTENTS 1.0 SCOPE AND APPLICATION ... sample size) in a drying oven set at 80oC. The tissue will be dried for 24 - 48 hours, cooled in a desiccator jar, and reweighed (dry weight). The tissue will be weighed at 4 to

More Product
Standard Operation Procedures (SOP) for IITA Seedbank

Standard Operation Procedures (SOP) for IITA Seedbank

the drying room. 6. Seed drying • Transfer the ranked trays to the drying room (relative humidity: 10–15%; Temperature: 16–18 oC). • Then arrange the seed bags serially on the dehydration shelves. (Figs. 9 a and b). • Turn the seed bags upside down every 2–3 days to allow homogeneous dehydration.

More Product
Standard Operating Procedure for - Fisher Sci

Standard Operating Procedure for - Fisher Sci

This standard operating procedure provides laboratory personnel with guidance on the procedure for determining TSS. This method is limited to the determination of ... Drying oven adjusted to 104 1C. Aluminum weighing dishes (or equivalent). Analytical balance capable of reading to 0.1 mg. 11 Reagents and standards .