looking for suitable laboratory equipment?

Our professionals are available 24*7. You can call us any time.

To understanding
How Rotary Evaporator Flow -

How Rotary Evaporator Flow -

3 Check that the power is switched on for the rotary evaporator and the heating bath. Turn on the cooling water for the rotary evaporator. Check that you have a gentle flow of cooling water, and not full power. 4 Attach your round-bottom flask and the adapter to the ground glass joint of the vapour tube of the rotary evaporator. Get Details

More Product
Rotary Evaporator -

Rotary Evaporator -

A rotary evaporator (sometimes abbreviated to rotavap) is a piece of equipment primarily used to remove solvent from a sample through “evaporation under reduced pressure”. The presence of reduced pressure in the apparatus causes the solvent (in the round bottom flask) to boil at a lower temperature than normal.

More Product
How to evaporate out water and methanol by using rotary evaporator?

How to evaporate out water and methanol by using rotary evaporator?

Anand Agricultural University. In rotary evaporator, you should maintain the temperature and vacuum according to solvent. Vitor sir is right, in general 40C is suitable of methanol, but when its ...

More Product
Selecting a Suitable Chiller for Your Rotary Evaporator

Selecting a Suitable Chiller for Your Rotary Evaporator

Apr 04, 2019 When shopping for an appropriate chiller for your setup, the most important factors to consider are: Minimum temperature and cooling capacity. Pump pressure. Pump flow rate. In this post, we explain these factors in detail to help you find the right chiller for the job. 1. Minimum Temperature and Cooling Capacity.

More Product
What is a rotary evaporator? - Kalstein

What is a rotary evaporator? - Kalstein

Aug 20, 2021 A rotary evaporator is a laboratory device used for the removal or recovery of solvents at low pressure. As its name indicates, it evaporates substances through the process of distillation, to later be condensed and later its components separated one by one. These equipment have existed in laboratories around the world since the 1960s, when the ...

More Product
Training Paper - Distillation with a Rotary Evaporator

Training Paper - Distillation with a Rotary Evaporator

BCHI Training papers Distillation with a Rotary Evaporator 4 Advantages of the rotary evaporator (compared with static apparatus) Rotary evaporators are used for: 3 3.1 Rotavapormodels 3.3.1 Glass assembly With a vacuum rotary evaporator you can carry out single-stage distilla-tion runs quickly and gently. The evaporation capacity of a ...

More Product
Rotary Evaporators Fisher Scientific

Rotary Evaporators Fisher Scientific

Bump Trap, 250mL, Rotary Evaporator, Modified, 24/40 Top Outer, 14/20 Lower Inner. Similar to CG-1320, but with the addition of two 4mm drain holes at the base of the inner tube to allow solvent to drain back into the evaporation flask. Traps have a 24/40 top outer joint and the listed size of lower inner joint.

More Product
IKA Rotary Evaporators - Frequently Asked Questions

IKA Rotary Evaporators - Frequently Asked Questions

Frequently Asked Questions - Rotary Evaporators. What minimum vacuum can be reached with the RV 10 rotary evaporator system (with coated glassware)? If all vacuum connections are sealed vacuum tight and the vacuum system is strong enough, down to 1mBar. Is it better to use a vertical or a diagonal condenser? It does not matter for the application.

More Product
Standard Operating Procedure - Rotary Evaporator

Standard Operating Procedure - Rotary Evaporator

hot bath. Since water is typically present in the hot bath, the heating system will not heat above 100 degrees. 14. If you have not already turned on the rotary evaporator, press the power button on the rotary evaporator control panel. 15. Use the dial on the rotary evaporator control panel to set the desired spin speed of the condenser. 16.

More Product
Laboratory Technique - Rotary Evaporator Optimization

Laboratory Technique - Rotary Evaporator Optimization

Jan 01, 2020 Ensure there is enough water to come up almost to the level of the rotary flask neck, covering 30-40% of the flask when fully lowered. Turn on the refrigeration unit to its lowest possible setting, below 0C is ideal. Turn on the vacuum pump. Set flask rotation to about 100 revolutions per minute (RPM).

More Product
Rotary evaporation vs freeze drying in protein concentration

Rotary evaporation vs freeze drying in protein concentration

Jun 02, 2021 Please note: the rotary evaporation was performed with a 60C heating bath, 20C cooling temperature, 1 L evaporating flask at 280 rpm. As you can see, water has a much lower distillation rate compared to methanol and ethanol on a rotary evaporator. Water is the easiest solvent to isolate with a freeze dryer.

More Product
Rotary Evaporator - rotary vacuum evaporator Latest Price ...

Rotary Evaporator - rotary vacuum evaporator Latest Price ...

Lab Rotary Vacuum Evaporator Buchi. ₹ 41,000 Get Latest Price. Specifications: - The evaporating flask, pear shaped to give a larger surface area for evaporation, is clamped to a glass duct which goes through the drive unit and protrudes 120 mm. into the condenser.

More Product
Rotary Evaporation - Science topic - ResearchGate

Rotary Evaporation - Science topic - ResearchGate

May 12, 2022 Question. 5 answers. Jan 17, 2019. 200 g fresh fruit puree is extracted with 200 ml of solvent on orbital shaker then filtration and desolvinization in rotary evaporator to obtain dry extract of ...

More Product
Do Rotary Evaporators Need Chillers? - BV Thermal Systems

Do Rotary Evaporators Need Chillers? - BV Thermal Systems

May 30, 2019 Typically, a chiller will pump cool fluid (typically water or a water/glycol mixture) to the process to remove the heat and the warm fluid returns to the chiller. Rotary Evaporator Chillers Chillers for Rotary Evaporators must have a high cooling capacity because of the high temperature of the solvent vapor.

More Product
Industrial Rotary Evaporators - LPP Group

Industrial Rotary Evaporators - LPP Group

Our range of BUCHI industrial rotary evaporators are used in pilot and kilo labs as well as production facilities in various industries. Typical applications of industrial rotary evaporators include distillation, concentration, solvent recovery (recycling), drying, (re-)crystallization and reflux distillation. We offer complete solutions for ...

More Product
Rotary Evaporator Rotovap Evaporation Distillation - Labstac

Rotary Evaporator Rotovap Evaporation Distillation - Labstac

Rotary Evaporator is an essential instrument in laboratory for the efficient and gentle removal of solvents from samples by evaporation. Besides, it provides excellent distilling solution in a wide range of applications. It can be used as a multi-functional system in combination with vacuum pump, vacuum controller and circulating refrigerators which makes it an unique choice for the …

More Product
General Laboratory Equipment - Rotary Evaporators - Asynt

General Laboratory Equipment - Rotary Evaporators - Asynt

Rotary Evaporators. We offer a wide range of rotary evaporators from manufacturers such as Buchi, Steroglass, Genser and IKA. Choose from different rotation speeds, specialist glassware, manual or automated models and much more to ensure you have the …

More Product
Lab Scale Rotary Evaporator Manufacturer from Thane

Lab Scale Rotary Evaporator Manufacturer from Thane

Rotary Vacuum Evaporator with : Motorized lift with manual by-pass in case of power failure available as standard. Digital RPM indication with AC drive. Rotation speed: 30 to 270 rpm; Digital water cum oil Bath: Temp range ambient + 5C to 180C. Vertical Glass Set - consisting of: Flask Adapter B-29 Pear Shaped Evaporating flask cap. 1 lit B-29

More Product
Key Principles of Rotary Evaporation -

Key Principles of Rotary Evaporation -

Sep 30, 2021 Rotary Evaporation Working Principles. Rotary evaporation works on the principle that reducing the pressure on the solvent results in the analytes within have a lower evaporation point than at atmospheric pressure. Rotary evaporation is used in both preparative and analytical organic chemistry and can assist users in fractionating liquid-phase ...

More Product
Rotary Evaporators Fisher Scientific

Rotary Evaporators Fisher Scientific

Temperature Range (Metric) 20C to 210C: Display: ... compact recirculating chiller for one rotary evaporator, particularly suitable for the Rotavapor R-100. ... Rotavapor™ R-300 has an ergonomic handle for easy positioning of the 1 L evaporation flask in to and out of the water bath B-301. Features an electronic lift, cold trap condenser ...

More Product
Rotary Evaporation - an overview ScienceDirect Topics

Rotary Evaporation - an overview ScienceDirect Topics

Thin films of lipids are prepared by rotary evaporation from solutions in dichloromethane (CH 2 Cl 2).The lipid film is rehydrated with an aqueous solution of the reactant and/or other additives and agitated at a temperature above T c until the film has completely detached from the flask (Fig. 12.4).This results in the separation of the lipid sheets, which close on themselves to form a ...

More Product
Latest News
X

CONTACT US

If you are interested in our products, please contact us, your satisfaction is our eternal pursuit!