How to use a Rotary Evaporator

How to use a Rotary Evaporator

Apr 01, 2010 The flask with the solution is placed on the rotary evaporator. The use of a bump trap prevents the solution from accidentally splashing into the condenser (and being contaminated). It is highly advisable to start with a clean bump bulb in case something bumps over after all! This would allow the experimenter to recover the solution or solid. 3.

More Product
Rotary Evaporation Techniques For Higher-Quality Cannabis ... - JULABO USA

Rotary Evaporation Techniques For Higher-Quality Cannabis ... - JULABO USA

As cannabis production becomes more mainstream, processors are using techniques like rotary evaporation to create higher-quality products.

More Product
Do You Know the Function of Each Rotovap Parts? - Lanphan

Do You Know the Function of Each Rotovap Parts? - Lanphan

Aug 16, 2017 Rotovap is commonly known as rotary evaporator, it’s a chemical laboratory use device which mainly used for the purpose of efficient and gentle removal of solvents from samples by evaporation. A general rotovap consists of several parts, each rotovap parts plays a different function. Following is the main rotovap parts and its function.

More Product
Buchi 20/40/60 rule for Rotary Evaporators

Buchi 20/40/60 rule for Rotary Evaporators

Doc: CHEMFS rotovap pressure-temp Custodian: Dept. Chem. School Safety Coordinator Page 1 of 1 Created: Feb 2005 Last Review : Dec 2010 Next Review: Dec 2013 ... The cooling water temperature should be below 20oC. 3. Adjust the needed vacuum for a solvent boiling point of 40oC according to list below. Reference: Buchi: List of Solvents .

More Product
Rotovap Startup - csustan.edu

Rotovap Startup - csustan.edu

E. Fill the water bath with clean, deionized water only. • This will minimize hard-water scale buildup. • If the water is scummy, change it. • If you drop your flask in the bath, you'll thank yourself for keeping it clean. F. Do not monopolize the rotovap. • If others are waiting, be courteous and mindful of your use. G. Do not abuse ...

More Product
Why Is Ice A Compound? [Comprehensive Answer]

Why Is Ice A Compound? [Comprehensive Answer]

Ice in Water The atoms of water are distributed differently in the ice from in the liquid water, and the ice can be physically separated from the water, making it a mixture. Once the ice melts, the two can no longer be separated, so it is no longer a mixture. Is ice a element?

More Product
Rotovapping Aqueous Solutions - Chemistry Stack Exchange

Rotovapping Aqueous Solutions - Chemistry Stack Exchange

Ideally you should have pump attached to dry ice/acetone trap followed by a cold water condenser (from the rotovap). There are several reasons to have a cold trap. Protection of the pump is one of them. The other reason is that a pump can maintain deep vacuum OR pump large volume of material, but not both. By capturing solvents in the trap you ...

More Product
Rotovap - Dartmouth College

Rotovap - Dartmouth College

Important Features of the Rotovap. 1) The vacuum pump is the source of reduced pressure in the system. 2) Spin speed and bath temperature control knobs. 3) Water bath. 4) Bump guard. 5)Cold finger. (Please do not use the rotovap if the finger is not cold. There should be excess solid dry ice in the finger.) 6)Vacuum release valve.

More Product
Rotavaping DMF - MJLPHD

Rotavaping DMF - MJLPHD

Jan 10, 2014 To rotavap DMF, Dow Corning high vacuum grease must be freshly applied to the joins and Keck clips used to hold the flask onto a non-reversible splash-guard. With the water bath at 55 C the vacuum will need to be lowered to 25 Torr; at 70 C the required vacuum is only 25 Torr. A 100 mL pre-weighed flask and a 500 mL non-reversible splash ...

More Product
Precautions for Using a Water Bath in the Rotovap

Precautions for Using a Water Bath in the Rotovap

Jan 16, 2019 Place the water bath in the center place where the evaporation flask is lifted vertically. Lower the host of the rotary evaporator slowly. Lower the evaporation flask until it is nicely placed inside the water bath. Add water into the water bath according to the capacity of the evaporation flask. Don’t add too much water.

More Product
Rotovap Distillation: What Is A Rotary Evaporator? - BVV

Rotovap Distillation: What Is A Rotary Evaporator? - BVV

Jul 21, 2017 Understanding Rotovap Distillation. Before learning about rotovap setup and operation, you must have a clear picture of the physical change happening inside of the rotary evaporator. Consider how a mixture containing extract and ethanol must first be separated before rotovap distillation can occur.

More Product
Standard Operating Procedure: Rotovaps - Chemistry

Standard Operating Procedure: Rotovaps - Chemistry

Jun 06, 2016 Prior to turning on the pump, the rotation should be turned on and the stopcock valve located at the top of the instrument should be in the closed position to ensure you do not accidentally apply vacuum to your system. Select the pump you wish to use and power it on. Then slowly apply vacuum to your rotovap system by regulating the stopcock ...

More Product
How to Speed Up Your Rotary Evaporation Process

How to Speed Up Your Rotary Evaporation Process

Jun 26, 2019 Ideally, an evaporation flask should never be more than half full, both to prevent spillage and allow enough liquid surface area for efficient evaporation. 3. Increasing the Bath Temperature. The water bath is responsible for one of the ways in which a rotovap speeds up evaporation. The water bath heats the solvent, increasing the rate of ...

More Product
Ethanol Removal in Cannabis Applications Blog

Ethanol Removal in Cannabis Applications Blog

Oct 31, 2019 Optimal Rotovap Operating Conditions for Ethanol Removal. The recommended vapor temperature for ethanol extraction is 25–30C. Boiling ethanol at 30C requires a pressure of 123 mbar, and boiling at 25C requires a pressure of 95 mbar. The 20/40/60 rule offers a general guideline for rotovap operating conditions.

More Product
Home Environmental Health Safety UCI

Home Environmental Health Safety UCI

Once the evaporation is complete conduct the same steps in the reverse order: turn off the hot water bath, remove the flask from the water, stop the rotation, turn off the vacuum, slowly open the stopcock to vent the system (remove residual vacuum) while holding the flask (to avoid it falling and breaking), and remove the flask.

More Product
Home Environmental Health Safety UCI

Home Environmental Health Safety UCI

Remove the water from the hot water bath when finished using the rotovap, this will prevent it from evaporating and leaving behind a residue. Residues are difficult to remove and decrease the efficiency of the water bath. Also, change the water regularly to …

More Product
Rotary Evaporator Fact Sheet - UMass Amherst

Rotary Evaporator Fact Sheet - UMass Amherst

solvent) and clog traps. Water aspirators should not be used as these can allow solvent vapors to enter drains and waste large volumes of water. 5. Check all glassware for visible chips, cracks or scratches before using. Handle glassware with care at all times. 6. Always use a cold trap in between the rotovap and the pump. Never use a liquid

More Product
NURS 2150 PEDS-PREPU Cardiopulmonary_LATEST 100

NURS 2150 PEDS-PREPU Cardiopulmonary_LATEST 100

The nurse should instruct the client to: a) hold his nose while bending forward at the waist. b) lie supine with his neck extended. c) sit upright, leaning slightly forward. d) blow his nose and then put lateral pressure on his nose. The nurse is caring for …

More Product
Solvent Removal - Organic Chemistry at CU Boulder

Solvent Removal - Organic Chemistry at CU Boulder

Use a Keck clip to secure the flask to the apparatus. Make sure the water flow to the cooling coils is turned on. Turn on the motor so that the flask rotates. Usually the flask containing the solution to be evaporated is warmed by a water bath; consult your TA to see if it is necessary. Make sure the vent at the top of the cooling coils is closed.

More Product
Solved Chem lab: Acid/base extraction: the bicarbonate

Solved Chem lab: Acid/base extraction: the bicarbonate

Why wasn’t the water removed by a rotovap instead? This problem has been solved! See the answer See the answer See the answer done loading. Chem lab: Acid/base extraction: the bicarbonate solution (Acetylsalicylic Acid + aqueous NaHCO3) was acidified with HCl to precipitate out acetylsalicylic acid. Why wasn’t the water removed by a rotovap ...